China MR-D02 Multi-Component Gas-Liquid Mixing Meter - Dynamic Gas Distribution Supplier & Factory
Main Features
Support simultaneous and mixed gas distribution of gas and liquid.
Flow control adopts closed-loop fuzzy control technology, with fast response and accurate flow control.
Zero air pressure and cylinder air pressure can be monitored in real time to ensure that the air supply pressure meets the instrument requirements.
Large LCD screen, Chinese display, simple and convenient operation.
The liquid heating device used can reach up to 350℃, the temperature is stable, and the liquid can be quickly vaporized.
Multi-channel calibration gas input interface eliminates the tedious work of replacing multiple cylinder gases.
Application Areas
Technical Parameters
| Flow accuracy | gaseity: ≤0.5% Liquid state: ≤1.5% |
| Flow linearity | ≤±0.3%F.S |
| Flow repeatability | ≤±0.2%F.S |
| Dilution gas flow range | 0~20SLM; 0~10SCCM; 0~50SCCM; 0~500SCCM (Can be selected according to needs) |
| Dilution ratio | 100:1 / 200:1 |
| Maximum ratio | 5000:1 (Can be customized according to customer needs) |
| Input pressure | 100Kpa~500Kpa |
| Display method | 800X480 liquid crystal 7 inch touch screen |
| Ambient temperature | -10℃~+50℃ |
| Environment humidity | <85%RH (No condensation) |
| Equipment pressure resistance | <1Mpa |
| Working pressure difference range | 0.05Mpa~0.3Mpa |
| Working power supply | 110VAC~240VAC, 50±0.5Hz |
| Size | (483x195x452)mm |
| Weight | 25kg~30kg |
Frequently Asked Questions
What is the flow control accuracy for gas and liquid states?
The system achieves a flow accuracy of ≤0.5% for gaseous states and ≤1.5% for liquid states, supported by closed-loop fuzzy control technology.
What dilution ratios does the instrument provide?
Standard dilution ratios are 100:1 and 200:1, with maximum ratios reaching up to 5000:1 available through custom configuration based on client requirements.
How does the liquid vaporization system perform?
The built-in liquid heating apparatus can reach temperatures up to 350℃ with reliable stability, enabling rapid vaporization of liquid media.
Can the unit monitor gas cylinder pressure continuously?
Yes, both zero air pressure and cylinder air pressure are monitored in real time to ensure the continuous supply meets system operational demands.
What are the standard electrical and ambient requirements?
The equipment operates on 110VAC~240VAC (50±0.5Hz) within an ambient temperature range of -10℃ to +50℃ and relative humidity below 85% RH (non-condensing).