Inquiry
Form loading...
High-Precision MR-DF2 Dynamic Gas Distribution Instrument from China Suppliers and Factory for Accurate Gas Analysis
Hot Products
Products Categories
Featured Products

High-Precision MR-DF2 Dynamic Gas Distribution Instrument from China Suppliers and Factory for Accurate Gas Analysis

The MR series high-precision dynamic Gas Distribution Instrument is a cutting-edge device designed for dynamic gas distribution. Engineered with advanced imported mass flow controllers, this instrument precisely manages multiple gas outputs in varying proportions, enabling the dynamic formation of different gas concentrations. Ideal for testing key performance indicators such as linearity, accuracy, and repeatability in gas analyzers, it serves as an essential tool in the production, calibration, and maintenance of gas analysis instruments. As a leading manufacturer and supplier in China, our factory provides this fixed concentration gas generating device, making it a vital asset in any laboratory or industrial setting focused on gas analysis and testing

    Main Features

    • Complies with the relevant standards involving gas distribution instruments in HJ57-2017, HJ76-2017, HJ604-2017, HJ38-2017, supports gas mixing and distribution of multiple components, and can distribute ppb level, ppm level, percentage level, etc. concentration standard gas.

    • It can be customized according to customer needs for dual-channel, three-channel, multi-channel and other composite gas distribution.

    • It adopts high-quality components such as high-precision stainless steel mass flow controller, stainless steel quick-plug OD6/4mm gas interface, and high-precision rotor flowmeter to ensure high system gas distribution accuracy and reliable quality.

    • Large-size LCD screen, the system runs more stably and the operation is easier.

    • Adopts 19-inch 4U chassis, which is easy to integrate into the cabinet.

    • Flow control adopts closed-loop fuzzy control technology, with fast response and accurate flow control.

    • Zero air pressure and cylinder air pressure can be monitored in real time to ensure that the air supply pressure meets the instrument requirements.

    • The gas path cleaning function in the system can ensure the accuracy of each gas distribution and the long life of the equipment.

    • Dual output, automatically balances the inlet pressure of the detection equipment.

    • The gas distribution instrument is equipped with temperature compensation, so customers do not need to consider the influence of temperature on equipment operating data at different temperatures.

    • No preheating time is required, gas distribution can be started immediately after turning on the machine.

    • Independent intellectual property rights, including invention patents and software copyrights.

    Technical Indicators

    Mass flow controller range A variety of specifications can be selected according to user needs(0-5000ml/min、5000-10000ml/min etc.)
    Flow accuracy ≤1.0%
    Flow Distribution Uncertainty ≤0.6%
    Flow repeatability ≤0.2%
    Dilution factor When the flow rate is 2000-3000ml/min, the dilution factor is ≤50; when the flow rate is 5000-10000ml/min, the dilution factor is ≤100
    Turndown 100:1/200:1(Can be customized as required)
    Maximum ratio 1000:1/4000:1(Can be customized according to needs)
    Input pressure 100Kpa~500Kpa(Can be customized according to user needs)
    Usage environment temperature:0~50℃,humidity:0-90%RH
    Equipment pressure resistance <1Mpa
    Working pressure difference range 0.05Mpa~0.3Mpa
    Working power supply 110VAC~240VAC/50Hz
    Dimensions (483×195×452)mm(customizable)
    Weight 15Kg(Adjustable according to appearance)

    Frequently Asked Questions

    Q: Which standards does this gas distribution instrument comply with?

    The instrument complies with the relevant standards involving gas distribution instruments in HJ57-2017, HJ76-2017, HJ604-2017, and HJ38-2017. It supports the gas mixing and distribution of multiple components for ppb, ppm, and percentage level concentration standard gases.

    Q: Can the gas distribution channels be customized?

    Yes, the system can be fully customized according to customer needs to support dual-channel, three-channel, multi-channel, and other composite gas distribution configurations.

    Q: What is the flow control accuracy of the instrument?

    The instrument features a flow accuracy of ≤1.0%, a flow distribution uncertainty of ≤0.6%, and a flow repeatability of ≤0.2%, ensuring high system gas distribution accuracy.

    Q: Does the device require preheating time before operation?

    No preheating time is required. Gas distribution can be started immediately after turning on the machine, which helps improve workflow efficiency.

    Q: How does temperature affect the equipment's operating data?

    The gas distribution instrument is equipped with temperature compensation, meaning customers do not need to consider the influence of temperature on operating data at different temperatures.